FIRE RATING
Fire Retardant (FR) panel systems are a critical consideration for all wall and ceiling systems – no matter how simple or complex.
Decor Systems have a wide range of systems that are engineered to meet the most stringent industry fire standards. We offer a range of fire-resistant wall and ceiling acoustic panel selections to meet the compliance, design and functional elements of your project.
Our team of specialists will direct you and offer up-front professional advice that will ensure you are fully compliant to the Building Code of Australia, without having to compromise the creative schematics you have in mind.
A Group 1 material is one that does not reach flashover when exposed to 100 kW for 600 seconds followed by exposure to 300 kW for 600 seconds as determine by AS 5637
Non-combustible means:
Class of Building
|
Fire-isolated exits and fire control rooms | Public corridors | Specific Areas | Other Areas |
Class 2 or 3, Unsprinklered
Excluding accommodation for the aged, people with disabilities and children |
Walls: 1
Ceilings: 1 |
Walls:1, 2
Ceilings: 1, 2 |
Walls:1, 2, 3
Ceilings: 1, 2, 3 |
Walls:1, 2, 3
Ceilings: 1, 2, 3 |
Class 2 or 3, Sprinklered
Excluding accommodation for the aged, people with disabilities and children |
Walls: 1
Ceilings: 1 |
Walls:1, 2, 3
Ceilings: 1, 2, 3 |
Walls:1, 2, 3
Ceilings: 1, 2, 3 |
Walls:1, 2, 3
Ceilings: 1, 2, 3 |
Class 3 or 9a, Unsprinklered
Accommodation for the aged, people with a disability, children and health-care buildings |
Walls: 1
Ceilings: 1 |
Walls:1
Ceilings: 1 |
Walls:1, 2
Ceilings: 1, 2 |
Walls:1, 2, 3
Ceilings: 1, 2, 3 |
Class 3 or 9a, Sprinklered
Accommodation for the aged, people with a disability, children and health-care buildings |
Walls: 1
Ceilings: 1 |
Walls:1, 2
Ceilings: 1, 2 |
Walls:1, 2, 3
Ceilings: 1, 2, 3 |
Walls:1, 2, 3
Ceilings: 1, 2, 3 |
Class 5, 6, 7, 8 or 9b schools, Unsprinklered
|
Walls: 1
Ceilings: 1 |
Walls:1, 2
Ceilings: 1, 2 |
Walls:1, 2, 3
Ceilings: 1, 2 |
Walls:1, 2, 3
Ceilings: 1, 2, 3 |
Class 5, 6, 7, 8 or 9b schools, Sprinklered
|
Walls: 1
Ceilings: 1 |
Walls:1, 2, 3
Ceilings: 1, 2, 3 |
Walls:1, 2, 3
Ceilings: 1, 2, 3 |
Walls:1, 2, 3
Ceilings: 1, 2, 3 |
Class 9b other than schools, Unsprinklered | Walls: 1
Ceilings: 1 |
Walls:1
Ceilings: 1 |
Walls:1, 2
Ceilings: 1, 2 |
Walls:1, 2, 3
Ceilings: 1, 2, 3 |
Class 9b other than schools, Sprinklered | Walls: 1
Ceilings: 1 |
Walls:1, 2
Ceilings: 1, 2 |
Walls:1, 2, 3
Ceilings: 1, 2, 3 |
Walls:1, 2, 3
Ceilings: 1, 2, 3 |
Class 9c, Sprinklered | Walls: 1
Ceilings: 1 |
Walls:1, 2
Ceilings: 1, 2 |
Walls:1, 2, 3
Ceilings: 1, 2, 3 |
Walls:1, 2, 3
Ceilings: 1, 2, 3 |